APC Rack PDU 2G, Metered, ZeroU, 5.7kW, 208V, (36) C13 & (6) C19 & (2) 5-20 - AP8861 .Not suitable for use in UK, check suitability before ordering

Frontpage APC Rack PDU 2G, Metered, ZeroU, 5.7kW, 208V, (36) C13 & (6) C19 & (2) 5-20 - AP8861 .Not suitable for use in UK, check suitability before ordering
APC Rack PDU 2G, Metered, ZeroU, 5.7kW, 208V, (36) C13 & (6) C19 & (2) 5-20 - AP8861 .Not suitable for use in UK, check suitability before ordering (AP8861)

APC Rack PDU 2G, Metered, ZeroU, 5.7kW, 208V, (36) C13 & (6) C19 & (2) 5-20 - AP8861 .Not suitable for use in UK, check suitability before ordering

SKU:
AP8861
EAN:
0731304277057
  • TYPE PDU
€1 661,00
€1 339,52  ex. sales tax
Expected in stock 12.4.2024
Description

Rack PDU 2G, Metered, ZeroU, 5.7kW, 208V, (36) C13 & (6) C19 & (2) 5-20


APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Includes

Installation guide, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable

Output

  • Nominal Output Voltage 120V,208V
  • Maximum Total Current Draw per Phase 20A
  • Output Connections (36) IEC 320 C13
  • (6) IEC 320 C19
  • (2) NEMA 5-20R
  • Overload Protection No

Input

  • Nominal Input Voltage 208V 3PH
  • Input Frequency 50/60 Hz
  • Regulatory Derated Input Current (North America) 16A
  • Input Connections NEMA L21-20P
  • Cord Length 1.83 meters
  • Number of Power Cords 1
  • Maximum Line Current per phase 20A
  • Maximum Input Current per phase 20A

Physical

  • Net Weight 6.34 KG
  • Maximum Height 1791.00 mm
  • Maximum Width 56.00 mm
  • Maximum Depth 44.00 mm
  • Shipping Weight 7.97 KG
  • Shipping Height 2000.00 mm
  • Shipping Width 162.00 mm
  • Shipping Depth 107.00 mm
  • Color Black

Environmental

  • Operating Environment -5 - 45 °C
  • Operating Relative Humidity 5 - 95%
  • Operating Elevation 0-3000 meters
  • Storage Temperature -25 - 65 °C
  • Storage Relative Humidity 5 - 95%
  • Storage Elevation 0-15000 meters

Conformance

  • Regulatory Approvals CSA C22.2 No. 60950,UL 60950-1
  • Standard Warranty 2 years repair or replace
  • Environmental Compliance RoHS,REACH: Contains No SVHCs,Contains Lithium Battery

Features & Benefits

Availability

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Agility

Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Please note that although care has been taken in the degree of relevancy, pictures are for display purposes only, and product appearance may differ from what you see. If there are any discrepancies between the product headline, description and picture, the correct information will be in the product headline (i.e. computer systems may not come with monitors even if pictured that way). If anything is unclear, please email support before placing your order.